aGent-R

Gamma Radiation Warning Device “aGent-R”

A wrist-type radiation detection watch in a shock-resistant body with a high ingress protection rating IP67. Geiger counter watch aGent-R is designed for detection and evaluation of gamma radiation using a four-level threshold alarm system. LED and vibrating alarms warn about threshold levels exceeding. The function of non-stop counter-performance monitoring guarantees the accuracy of measurement results.

280 

Description

aGent-R – Gamma Radiation Warning Device

A wrist-type radiation detection watch in a shock-resistant body with a high ingress protection rating IP67. Geiger counter watch aGent-R is designed for detection and evaluation of gamma radiation using a four-level threshold alarm system. LED and vibrating alarms warn about threshold levels exceeding. The function of non-stop counter-performance monitoring guarantees the accuracy of measurement results.

Purpose of Use:

  • Detection of the increased levels of gamma radiation and their estimation by means of the four-level threshold alarm system

Features:

  • Wrist warning device
  • Non-stop performance monitoring of the warning device
  • LED and vibrating alarm of threshold levels exceeding with the option to turn off the vibrating alarm
  • Non-stop performance monitoring of the built-in Geiger-Muller counter
  • Manual control of the built-in vibration instrument and residual capacity of batteries with the corresponding LED indication
  • Periodic vibrating and LED alarm when residual battery capacity becomes less than 10%
  • Automatic vibrating and LED alarm when residual battery capacity is less than 5 %, with the following switching-off of the warning device
  • Two АААА batteries
  • Shock-resistant plastic housing with IP67 ingress protection rating

Specifications:

  • Dynamic range of gamma radiation registration from 10 μR/h to 1000 R/h.
  • Energy range of gamma radiation registration from 0.05 to 3.0 MeV.
  • Threshold level values of gamma radiation dose rate:

– 100 μR/h;

– 1.0 mR/h;

– 100 mR/h;

– 10 R/h;

  • Relative error in threshold levels determination ± 25 %.
  • Time of continuous operation with new batteries – not less than 1300 hours*.
  • Operating temperatures range – from -20 to + 50 °С.
  • Weight – 80 g.
  • Dimensions without a strap – 55×55×27 mm.
  • Mean time between failures – not less than 6000 hours.
  • Average service life – not less than 6 years.
  • Average shelf life – not less than 6 years.

* provided that background radiation is normal (less than 100 μR/h), ambient air temperature is within 20±2°С, and the battery is tested not more than 3 times per 24 hours.

Delivery Kit:

  • “aGent-R” gamma radiation warning device
  • Batteries
  • Leather case with a clip
  • Operating manual
  • Packing box